| Increase Volume, Lower Operating Cost |
| Replace conventional atmospheric non-condensing hot water heaters with the Laars Mark II 9600 HWG Hot Water Generator and reduce annual operating costs by 40%. |
| The Laars Mark
II 9600 HWG is a gas-fired condensing hot water heating boiler that uses a secondary stainless steel
heat exchanger to deliver combustion efficiencies as high as 90% and
thermal efficiencies as high as 96% by capturing
heat that would normally be lost up the chimney and transferring it into
the water flowing through unit.
Its compact, low mass design
eliminates the standby and radiation losses typically suffered by larger storage-type water
heating boilers because the HWG's heat exchanger heats instantly upon
demand. Pilotless, self-monitoring sealed combustion system is direct-vented and does not require a metal chimney or flue or draft inducer. A built-in fan draws all combustion air from outdoors through a plastic pipe and forces it back out of the unit through a separate plastic pipe. Standard PVC, CPVC or ABS plastic piping may be used. The HWG, weighing between 222 to 235 pounds, can be installed on combustible floors and requires only 1" clearance to combustibles from the jacket. |
|
| | Performance Ratings | Hot Water Recovery | Parts | |
|
Mark II 9600 HWG
Performance Ratings Fuel energy input and heat energy output in BTU's per hour x 1000 (MBH); NOx levels in parts per million (ppm); and approximate shipping weight in pounds.
|
||||||||||||||||||||||||||||||||||||||||||
| Return to Top of Page |
|
Mark II 9600 HWG Hot
Water Recovery Gallons of hot water delivered per hour (GPH) at the indicated temperature (°F).
|
| Return to Top of Page |
| Mark
II 9600 HWG Warranty
|
| Twenty (20) year limited manufacturer's warranty. |
| FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician, qualified in hot water boiler installation and maintenance. Improper installation and/or operation could create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death. Improper installation and/or operation will void the warranty. |
| Return to Top of Page |
| Central Florida Representative:
|
Manufacturer:
|
| Conservation Systems, Inc. 5850 Lakehurst Drive, Suite 120 Orlando, FL 32819-8386 407.351.9121 Phone 407.352.6391 Fax www.csiworldwide.com |
Laars Heating Systems Co. A subsidiary of Bradford White Corporation 1355 Kuehner Drive Simi Valley, CA 93063-4478 1-800-900-9276 www.laars.com |
| Specifications subject to change without notice. | |
| Please read our Terms of Sale notice carefully before placing an order. | |
| Site Copyright 2006 © Conservation
Systems, Inc. Orlando, Florida USA All other trademarks, logos and copyrights are the property of their respective owners. |
|
| Return to Top of Page | |