Increase Volume, Lower Operating Cost
Replace conventional atmospheric non-condensing hot water heaters with the Laars Mark II 9600 HWG Hot Water Generator and reduce annual operating costs by 40%.
The Laars Mark II 9600 HWG is a gas-fired condensing hot water heating boiler that uses a secondary stainless steel heat exchanger to deliver combustion efficiencies as high as 90% and thermal efficiencies as high as 96% by capturing heat that would normally be lost up the chimney and transferring it into the water flowing through unit. Its compact, low mass design eliminates the standby and radiation losses typically suffered by larger storage-type water heating boilers because the HWG's heat exchanger heats instantly upon demand.
 
Pilotless, self-monitoring sealed combustion system is direct-vented and does not require a metal chimney or flue or draft inducer. A built-in fan draws all combustion air from outdoors through a plastic pipe and forces it back out of the unit through a separate plastic pipe. Standard PVC, CPVC or ABS plastic piping may be used.
 
The HWG, weighing between 222 to 235 pounds, can be installed on combustible floors and requires only 1" clearance to combustibles from the jacket.
 
Submittal Data Sheet for LAARS 9600 HWG Water Heater in Adobe Acrobat PDF format (Adobe Acrobat Reader required to view). Submittal Data
Submittal Data Sheet for LAARS 9600 HWG Water Heater in Adobe Acrobat PDF format (Adobe Acrobat Reader required to view). Owner's Manual

LAARS 9600 HWG Hot Water Generator

| Performance Ratings | Hot Water Recovery | Parts |
    
Mark II 9600 HWG Performance Ratings
Fuel energy input and heat energy output in BTU's per hour x 1000 (MBH); NOx levels in parts per million (ppm); and approximate shipping weight in pounds.
Model Input Output NOx Levels Thermal Efficiency Weight
HWG-M2- 150 150 135 219 96% 222
HWG-M2-175 175 158 340 96% 222
HWG-M2-200 199 180 388 96% 222
HWG-M2-250 NAT 250 223 480 96% 235
HWG-M2-250 PRO 240 214 462 96% 235
Thermal efficiency measures the effectiveness of the heat exchanger to transfer energy from the combustion process to water.
Return to Top of Page
      
Mark II 9600 HWG Hot Water Recovery
Gallons of hot water delivered per hour (GPH) at the indicated temperature (°F).
Model 100°F 80°F 60°F
HWG-M2- 150 173 216 219
HWG-M2-175 202 253 340
HWG-M2-200 231 289 388
HWG-M2-250 NAT 288 360 480
HWG-M2-250 PRO 277 346 462
Return to Top of Page
 
Mark II 9600 HWG Warranty
Twenty (20) year limited manufacturer's warranty.
FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician, qualified in hot water boiler installation and maintenance. Improper installation and/or operation could create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death. Improper installation and/or operation will void the warranty. 
Return to Top of Page
 
Central Florida Representative:
Manufacturer:
Conservation Systems, Inc.
5850 Lakehurst Drive, Suite 120
Orlando, FL 32819-8386
407.351.9121 Phone
407.352.6391 Fax
www.csiworldwide.com
Laars Heating Systems Co.
A subsidiary of Bradford White Corporation
1355 Kuehner Drive
Simi Valley, CA 93063-4478
1-800-900-9276
www.laars.com 
 
Specifications subject to change without notice.
Please read our Terms of Sale notice carefully before placing an order.
Site Copyright 2006 © Conservation Systems, Inc. Orlando, Florida USA
All other trademarks, logos and copyrights are the property of their respective owners.
Return to Top of Page