csiweb > residential heating > horizon

LAARS
Horizon Oil-Fired Boiler
CSI CONSERVATION SYSTEMS INC 407.351.9121    CONTACT    HOME
 
High Efficiency Oil
The LAARS Horizon is a highly efficient oil-fired hydronic heating boiler engineered to maximize the transfer of energy from the combustion process directly into the water flowing through the unit by increasing heat retention in the base and chamber. Its wet base, three pass, horizontal tube design is capable of reliably providing five gallons per minute of domestic hot water.
Built to last a lifetime, the Horizon's solid steel construction is up to fifty percent stronger than competing cast iron designs and is backed with a non-prorated, limited lifetime warranty on its ASME shell.

Raised coil flanges, stainless steel baffles, and easy to remove covers simplify cleaning and maintenance.
 
Other Horizon features include: three-pass design; two fully insulated hinged front doors for easy cleaning access; easy rear flue box cleanout access; built-in automatic circulator; front-mounted temperature and pressure gauge; precision Honeywell temperature control; choice of Beckett, Blue Angel or Riello oil burners.

Brochure
Manual
Warranty
 
| Performance Ratings | Specifications | Parts |

LAARS Horizon Oil-Fired Boiler

 
Horizon Performance Ratings
Fuel energy input (D.O.E. heating capacity) and net heat energy output in BTUs per hour x 1000 (MBH); firing rate (fuel consumption); annual fuel utilization efficiency (AFUE); net stack temperature; and coil capacity (maximum amount of heated water that can be delivered per minute).
Model 100 125 145 175 205 240 270 300
Input MBH 100 125 145 175 205 240 270 300
Output MBH 87 109 126 157 178 209 235 261
Firing Rate GPH 0.85 1.00 1.25 1.50 1.75 2.00 2.25 2.50
AFUE % 84.2 84.0 85.8 85.2 85.4 84.2 85.2 84.4
Stack Temp. °F 333 371 319 354 325 350 330 360
Coil Capacity GPM 5 5 5 5 5 5 5 5
Annual Fuel Utilization Efficiency (AFUE) refers to the the amount of heat actually delivered compared to the amount of fuel supplied expressed as a percentage (test completed at 299,000 BTUH input). AFUE includes includes most losses that occur under normal usage (stack loss, radiation, convection, standing pilot loss, etc.).
Return to Top of Page
 
Horizon Specifications
Smoke outlet diameter; water supply connection size; water capacity; and approximate shipping weight.
Model 100 125 145 175 205 240 270 300
Smoke Outlet in. 6 6 6 6 8 8 8 8
Water Supply Size in.
Water Capacity gals. 21 21 34 34 42 42 48 48
Approximate Weight lbs. 494 494 608 608 764 764 810 810
Return to Top of Page
 
Central Florida Representative:
Manufacturer:
Conservation Systems, Inc.
5850 Lakehurst Drive, Suite 120
Orlando, FL 32819-8386
407.351.9121 Phone
407.352.6391 Fax
www.csiworldwide.com
Laars Heating Systems Co.
A subsidiary of Bradford White Corporation
1355 Kuehner Drive
Simi Valley, CA 93063-4478
1-800-900-9276
www.laars.com 
 
Specifications subject to change without notice.
Please read our Terms of Sale notice carefully before placing an order.